MODEL: FAIRY GRS 121 EI/JFR N3
- Nominal Power kW: 2.70 2.80
- Rated Ratio Btu / h: 9.212 9.554
- Design Load (Pdesign) (C / A / W) *: 2.70 2.70 / 2.60 / 2.80
- Performance Range kW: 0.45-3.50 0.45-3.60
- Performance Range Btu / h: 1.535 - 11.942 1.706 - 12.283
- Consumption (min-nom-max) W: 90-820-1.400 160-755-1.500
- Operating current (nom) A: 3.7 - 6.3 3.4 - 6.8
- SEER - SCOP (C / A / W) - W / W CLASS: 6.8 A ++ 3.2B / 4.0A + / 5.1A +++
- Operating range oC: -15 ~ 43 -15 ~ 24
- V-Ph-Hz electrical supply: 230V ~ 1N - 50Hz
- Power Supply Cable / Ass. Mm2: 3x1.5 - OXI / 4x1.5
- Compressor type: GREE LANDA Rotary
- Expansion Type: Capillary
- Air supply m3 / h: 560/490/460/430/380/330/290
- Noise Pressure Level Es. (Y / M / X) - Eq. dB (A): 41/37/35/32/29/26/24 - 50
- Sound Power Level Es. (Y / M / X) - Eq. dB (A): 55/48/46/44/40/37/35 - 60
- Liquid Gas Gas Diameter inch: 1/4 "- 3/8"
- Refrigerant filling (original / over 5m): R32 - 0.55kg / 20g / m
- Maximum Length / Height of pipes: 19/10
- Dist. Int. Mon. WxHxB / Weight mm / kg: 790x275x200 / 9
- Dist. Ext. Mon. WxHxB / Weight mm / kg: 776x540x320 / 29.5...